Chapter 6: Programming Information

A794 Owner’s Guide

March 1999

98

Transmit Status (continued)

Cash Drawer Status (n = 2 or n = 50)
Bit

Off/On

Hex

Decimal

Status for Transmit Status

0

Off
On

00
01

0
1

One or both cash drawers open.
Both cash drawers closed.

1

Off
On

00
02

0
2

One or both cash drawers open.
Both cash drawers closed.

2

-

-

-

Undefined

3

-

-

-

Undefined

4

Off

00

0

Not used. Fixed to off.

5

-

-

-

Undefined

6

-

-

-

Undefined

7

Off

00

0

Not used. Fixed to off.

Flash memory User Sector Status (n = 4 or n = 52)
Bit

Off/On

Hex

Decimal

Status for Transmit Status

0

-

-

-

Undefined.

1

-

-

-

Undefined.

2

Off

00

0

Not Used. Fixed to off

3

Off
On

00
08

0
8

Flash Logo area adequate, definition stored
Flash logo area not adequate

4

Off

00

0

Not used. Fixed to off.

5

Off
On

00
20

00
32

No user-defined characters written to Flash
User-defined characters written to Flash

6

Off

00

0

Not used. Fixed to off.

7

-

-

-

Undefined.

Exceptions