Grass Valley K2 Media Client Service Manual Nov.18 2008 User Manual
Page 52

52
K2 Media Client Service Manual
July 28, 2008
Chapter 3 Service Procedures
b. Select the
Settings
tab.
c. Click
Modify Team
. A dialog box opens.
10.On the
Adapters
tab, do the following:
a. Select the top entry, which is
Intel® PRO/1000 MT Dual Port Server Adapter
(Type
I MB) or
Intel® PRO/1000 EB Network Connection with I/O Acceleration
(Type II
and Type III MB), and click
Set Primary
.
b. Select
Intel® PRO/1000 MT Dual Port Server Adapter #3
(Type I MB) or
Intel®
PRO/1000 MT Dual Port Server Adapter
(Type II and Type III MB) and click
Set
Secondary
.
11. Click
Name
tab and rename to Control Team.
12. Click
OK
and
OK
and to close dialog boxes.
13. Do not create a media team for the media (iSCSI) network. The two remaining
connections remain as independent ports and are used as follows:
• Media Connection #1, which is GigE port 2 on the K2 Media Client rear panel,
is the connection for the media (iSCSI) network on a non-redundant K2 Storage
System, or for the “A” media (iSCSI) network on a redundant K2 Storage
System.
• Media Connection #2, which is GigE port 4 on the K2 Media Client rear panel,
is not used on a non-redundant K2 Storage System. It is the connection for the
“B” media (iSCSI) network on a redundant K2 Storage System.
14. Restart the K2 Media Client.
Create the Control Team on systems shipping after 3.2.5x
Use this procedure if the K2 Media Client shipped from Grass Valley after release
3.2.5x in the Fall of 2007.
1. In Device Manager, right-click
…MT Dual Port Server Adapter
(Type I MB) or
…EB
Network Connection…
(Type II and Type III MB)
and select
Properties
. The
Properties dialog box opens.
2. Select the
Teaming
tab.