Qlogic, Quest controls inc, San fiber channel switches – Grass Valley iControl Supported Devices V.2 User Manual
Page 69: Telsec rm/wm-series controller

iControl
Supported Device Reference Guide
61
QLogic
SAN Fiber Channel Switches
The QLogic SAN Fiber Channel Switch family comprise a series of Fibre Channel (FC) protocol
switches for use as the backbone of storage area networks (SANs).
Quest Controls Inc.
TELSEC RM/WM-Series Controller
The TELSEC RM/WM-series controller is used to monitor/control environmental and access
control functions as well as equipment alarming at a remote site.
retries
If an SNMP request timeout, this defines the number of retries to be performed.
Default value:
1
.
timeout
Delay in seconds before declaring a timeout in the current SNMP request.
uniqueID
An extra identifier to be assigned to the plug-in to differentiate its alarms from the other
plugin of the same type. The
uniqueID
should be part of uri.
readCommunity
SNMP read community string. Use for SNMP polling.
Default value:
public
inputType
Defines the signal input type.
Value can be
DVB_S
,
ASI
or
IP
Default value:
DVB_S
outputType
Defines the signal output type.
Value can be
ASI
or
IP
Default value:
IP
Ordering information
Hardware
New in
iControl
version
GSM plug-in name
Order number
SNMP — QLogic SAN Fiber Channel Switches
IC-SNMP-202
Ordering information
Hardware
New in iControl
version
GSM plug-in name
Order number
"TELSEC RM/WM-Series Controller"
SNMP — Quest Telsec WM
IC-SNMP-149
(Continued)
Parameter