beautypg.com

Grass Valley iControl Supported Devices V.2 User Manual

Page 20

background image

Supported Devices

Comtech EF Data Corp.

12

Comtech’s DM240XR family of high-speed modulators support both DVB-S and DVB-S2
specifications. The DM240XR can easily be upgraded in the field. The DM240XR unit provides a
comprehensive set of advanced S2 features, and extends its dominance in broadcast
applications through increased data rate capability and the addition of 16APSK and 32APSK
support. Proven performance operating near Shannon's limit offers results with 30% better
bandwidth efficiencies and carrier to noise figures below the noise floor.

The plug-in supports three types of alarms:

Health alarms

,

Text alarms

, or

Bitfield alarms

, as

follows:

Health monitoring and text alarms

Alarm name

Type

MIB point

Polling

or

trap?

Further details

--- Health monitoring alarms ---

Device Communication

Status/health

sysUpTime

(RFC1213)

Poller

Device communication alarm set
by receiving a successful/failed
event in the poller

Device Restart

Status/health

sysUpTime

(RFC1213)

Poller

Raise a minor condition based on
the value of

sysUpTime

read is

smaller by at least 60 seconds
compared to last reading. The
value increase by 100 every
second.

System uptime

Text/health

sysUpTime

(RFC1213)

Poller

System up time alarm, this is a
default health monitoring alarm
when you use the

generic.js

to

create a new custom driver

--- Text alarms ---

(+) 5V Monitor

Text/health

radPlus5Volts

Fast
poller

+5V monitor with implied decimal
point. For example, a value of 51
represents +5.1 Volts.

(+) 12V Monitor

Text/health

radPlus12Volts

Fast
poller

+12V monitor with implied
decimal point. For example, a
value of 119 represents +11.9
Volts.

(-) 12V Monitor

Text/health

radMinus12Volts

Fast
poller

-12V monitor with implied decimal
point. For example, a value of -122
represents -12.2 Volts.

Active input of the RF
Port

Text/health

radRfSwitchActiveSide

Fast
poller

Indicates the active input of the RF
switch

Active PIIC Slot

Text/health

radActivePiicSlot

Fast
poller

Indicates the active PIIC slot

Connected Rf Switch
Side

Text/health

radRfSwitchConnectorSide

Fast
poller

Indicates the side of the RF switch
to which the modulator is
connected.