Supported Devices
MIBs Used
46
Alarm name
Type
MIB point
Further details
--- Converter alarms
cvalr
MIB point gives Local oscillator alarm and Power supply alarm.
mute
and
pol
are text alarms that only provide information
acvstat
MIB point gives informations for Redundancy Chain status alarms and serial link status
converter alarm.
Local Oscillator Alarm Status/health
cvalr
Local Oscillator Alarm
2
This alarm may occur if the specified converter is
not installed. It also may happen if the converter
cannot be selected with an SNMP set.
Power Supply Alarm
Status/health
cvalr
Power Supply Alarm
2
This alarm may occur if the specified converter is
not installed. It also may occur if the converter
cannot be selected with an SNMP set.
Mute
Text/health
mute
Mute converter output for the converter selected
by the most recent
cvsel
setting.
Polarization
Text/health
pol
Polarization setting for the converter selected by
the most recent
cvsel
setting.
Allowable settings:
• 0 - N/A
• 1 - None
• 2 - Horizontal
• 3 - Vertical
Serial Link Status
converter
StatusText/health
acvstat
Converter serial link status indicator
• 0 = No Fault - NSU-Converter Serial Link
enabled and communicating
• 1 = Fault - NSU-Converter Serial Link enabled
and not communicating
• 2 = No Fault - NSU-Converter Serial Link
disabled
• - = No Fault - Chain position inactive
Redundancy chain
status
StatusText/health
acvstat
Redundancy chain status indicator
• 0 = No Fault - chain position active
• 1 = Fault -chain position active (Fault reported
normally)
• 2 = Fault - chain position active both contacts
open
• 3 = Fault - chain position active both contacts
closed
• - = chain position inactive disconnected from
redundancy chain
• + = chain position inactive connected to
redundancy chain