Health alarms, Monitor alarms, Tx alarms – Grass Valley iControl Supported Devices V.2 User Manual
Page 30: Notify alarms

Supported Devices
Evertz
22
•
Health monitoring alarms
Alarm name
Type
MIB point
Polling or
trap?
Further details
--- Health monitoring alarms ---
Device
Communication
status/health
sysUpTime
(RFC1213)
Polling
Device communication alarm set by
receiving a successful/failed event in the
poller
Device Restart
status/health
sysUpTime
(RFC1213)
Polling
Raise a minor condition based on the value of
sysUpTime
read is smaller by at least
60 seconds compared to last reading. The
value increase by 100 every second.
System uptime
status/health
sysUpTime
(RFC1213)
Polling
System up time alarm, this is a default health
monitoring alarm when you use the
generic.js
to create a new custom driver
--- Monitor alarms ---
The device has sixteen SFP ports. The information on alarms will be displayed for each valid SFP on
the device.
Version
Text
Polling
Version number for the SFP module
Upgrade Support
Status
Polling
Indicates whether the SFP firmware can be
upgraded using the second stage bootloader
Serial number
Text
Polling
Serial number for SFP module
Id
Text
Polling
Describe the specific type of SFP
Class
Text
FC3405-MIB
Polling
Describe the base class of SFPs
--- TX alarms ---
TX data are on two cannons Laser A and Laser B, the information displayed is done for both tables
of index : laserA ( 1 ) , laserB ( 2 )
txBiasCurrent
Text
FC3405-MIB
Polling and
trap
Displays bias current on laser in units of
0.01 mA
txLaserEn
Text
Polling and
trap
Tells about SFPTX laser status
txLaserStatus
Text
Polling and
trap
Tells about wavelength supported by
SFPTX's lasers
txReclock
Text
polling and
trap
displays the reclocker status
txWavelength
Text
polling and
trap
tells about SFP TX laser status