Plug-in notes, This plug-in is based on, All mib points are static – Grass Valley iControl Supported Devices V.2 User Manual
Page 52

Supported Devices
Plug-in Notes
44
Certain parameters may be passed to the plug-in, as follows:
Plug-in Notes
• This plug-in is based on
generic.js
.
• All MIB points are static.
reference
Text/health
moreStatus
internal/external reference
polarization
Text/health
moreStatus
polarization (none, horizontal, vertical)
setup title
Text/health
moreStatus
Setup Title
slope
Text/health
moreStatus
Slope in dB
impedance
Text/health
moreStatus
50 ohm or 75 ohm
Parameter
Description
AlarmPath
Used to set the Alarm prefix.
Default:
PBI
.
Could be replaced by
IRD
so as to have legacy plug-ins tree look-like.
pollInterval
Poller interval in seconds. Overwrite the default interval of 20 seconds.
retries
If an SNMP request times out, this defines the number of retries to be performed.
Default:
1
.
timeout
Delay in seconds before declaring a timeout in the current SNMP request.
uniqueID
An extra identifier to be assigned to the plug-in to differentiate its alarms from the other
plug-in of the same type. The
uniqueID
should be part of the URI.
readCommunity
SNMP read community string. Use for SNMP polling.
Default:
public
pos15vThresh
Threshold for +15V voltage supervisor.
Default:
5V
The alarm +15V Supply rail becomes critical when the measured voltage is under the
threshold.
pos5vThresh
Threshold for +5V voltage supervisor.
Default:
2V
The alarms +5V Supply rail A and +5V Supply rail B become critical when the measured
voltage is under the threshold.
neg15vThresh
Threshold for -15V voltage supervisor.
Default:
5V
The alarm -15V Supply rail becomes critical when the measured voltage is above the
threshold.
(Continued)
Alarm name
Type
MIB point
Further details