--- Health monitoring alarms ---
These alarms are created by generic.js
Device
Communication
Status/health
sysUpTime
(RFC1213)
Raise a critical condition if the device stops
responding to polling for a time period defined
by pollinterval X retries.
Device Restart
Status/health
sysUpTime
(RFC1213)
Raise a minor condition based on the value of
sysUpTime
read is smaller by at least 60 seconds
compared to last reading. The value increase
by 100 every second.
--- Status alarms ---
Control Mode
Text/health
status
Control mode
• 0 = Local control
• 1 = Remote control
Redundancy Mode
Status/health
status
Redundancy mode
• 0 = Manual
• 1 = Automatic
Redundancy Chain
Position
Text/health
status
Chain position in standby
• 00 = Backup converter
• 01 = Primary converter 1
• 12 = Primary converter 12
Polarization
Text/health
status
Polarization switch position
• 0 = None
• 1 = Horizontal
• 2 = Vertical
Power Supply A
Status/health
status
Power Supply ‘A’ Alarm
Power Supply B
Status/health
status
Power Supply ‘B’ Alarm
Converter bus fault
Status/health
status
Converter bus fault
Converter Contact
fault
Status/health
status
Converter Contact fault
Switch Module fault
Status/health
status
Switch Module fault
Switch Module Bus
fault
Status/health
status
Switch Module Bus fault
write community
Status/health
writeCommunity
Check the write community defined in the device
correspond to the configured one. This is
important as the plug-in performs SNMP
SET
operations.
1. The switchover can monitor up to 12 converters + 1 backup.
2. This alarm can be set to
UNKNOWN
if
cvalr
data does not match the pattern ?abcdef.
3. This alarm can be set to
UNKNOWN
if converter cannot be selected with an SNMP set.
(Continued)
Alarm name
Type
MIB point
Further details