iControl

Supported Device Reference Guide

47

--- Health monitoring alarms ---

These alarms are created by generic.js

Device
Communication

Status/health

sysUpTime

(RFC1213)

Raise a critical condition if the device stops
responding to polling for a time period defined
by pollinterval X retries.

Device Restart

Status/health

sysUpTime

(RFC1213)

Raise a minor condition based on the value of

sysUpTime

read is smaller by at least 60 seconds

compared to last reading. The value increase
by 100 every second.

--- Status alarms ---

Control Mode

Text/health

status

Control mode

• 0 = Local control

• 1 = Remote control

Redundancy Mode

Status/health

status

Redundancy mode

• 0 = Manual

• 1 = Automatic

Redundancy Chain
Position

Text/health

status

Chain position in standby

• 00 = Backup converter

• 01 = Primary converter 1

• 12 = Primary converter 12

Polarization

Text/health

status

Polarization switch position

• 0 = None

• 1 = Horizontal

• 2 = Vertical

Power Supply A

Status/health

status

Power Supply ‘A’ Alarm

Power Supply B

Status/health

status

Power Supply ‘B’ Alarm

Converter bus fault

Status/health

status

Converter bus fault

Converter Contact
fault

Status/health

status

Converter Contact fault

Switch Module fault

Status/health

status

Switch Module fault

Switch Module Bus
fault

Status/health

status

Switch Module Bus fault

write community

Status/health

writeCommunity

Check the write community defined in the device
correspond to the configured one. This is
important as the plug-in performs SNMP

SET

operations.

1. The switchover can monitor up to 12 converters + 1 backup.
2. This alarm can be set to

UNKNOWN

if

cvalr

data does not match the pattern ?abcdef.

3. This alarm can be set to

UNKNOWN

if converter cannot be selected with an SNMP set.

(Continued)

Alarm name

Type

MIB point

Further details