Icontrol – Grass Valley iControl Supported Devices V.2 User Manual
Page 17

iControl
Supported Device Reference Guide
9
Alarm name
Further details
numberOfSignals
The number of signals configured in the PNC. The current PNC supports up to
4 signals. The maximum number of signals may change in future versions of
the PNC.
pncAppStartTime
PNC application start time:
where
:= 4 decimal digit year
:= 2 decimal digit month 1..12
:= 2 decmial digit day of month 1..31
:= 2 decimal digit hour 0..23
:= 2 decimal digit minute 0..59
:= 2 decimal digit second 0..59
pncAppStatus
PNC application status:
•
0
: Running OK
•
1
: Not running
•
2
: Starting up
•
3
: Shutting down
•
4
: Not installed
pncAppVers
PNC application version:
where
:= decimal major version number
:= 2 digit decimal minor version number
:= [a..z]
:=
:= text string name of the option
(e.g.
4.00g-
Bitmizer,Conditional_Access,Cue_Trigger,Disaster_Recovery,Dpi,MetroMu
x
)
pncPlatformStatus
Result of command:
prtdiag
found in
/usr/platform/sun4u/sbin
•
0
: no failures detected
•
1
: failures detected
pncPlatformSystemDate
Result of command:
/usr/bin/date
pncPlatformVers
Result of command:
/usr/bin/uname -a