beautypg.com

Figure 3-5, Connect the grounding terminal to the firewall -5 – H3C Technologies H3C SecPath F100-C-EI User Manual

Page 34

background image

Installation Manual
H3C SecPath F100-C-EI Firewall

Chapter 3 Installing the Firewall

3-5

(1) Grounding hole

(2) OT terminal

(3) Grounding screw

(4) PGND wire

(5) Grounding mark

Figure 3-5

Connect the grounding terminal to the firewall

To connect the PGND wire, follow the steps:

1) Remove the grounding screw from the chassis.
2) Insert the grounding screw into the OT terminal of the PGND

wire.

3) Fix the grounding screw with the OT terminal to the

grounding hole in the chassis, and fasten it with a screw
driver.

4) Connect the other end of the PGND wire to the earth ground.

Generally, the equipment room has a grounding strip, to
which you can connect the PGND wire of the firewall. To
connect the PGND wire to the grounding strip, peel 15 mm
of insulation sheath using a wire stripper, and wrap the bare
metal wire clockwise around the ground post. Then fix the
PGND wire to the ground post using a hex nut. If a
grounding strip is not available, connect the metal wire core
directly to the earth ground.