10-9
Follow these steps in user view to enable the display of system information on the console:
To do…
Use the command…
Remarks
Enable the monitoring of system
information on the console
terminal monitor
Optional
Enabled on the console and disabled on
the monitor terminal by default.
Enable the display of debugging
information on the console
terminal debugging
Required
Disabled by default
Enable the display of log
information on the console
terminal logging
Optional
Enabled by default
Enable the display of trap
information on the console
terminal trapping
Optional
Enabled by default
Outputting System Information to a Monitor Terminal
System information can also be output to a monitor terminal, which is a user terminal that has login
connections through the AUX or VTY user interface.
Outputting system information to a monitor terminal
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable information center
info-center enable
Optional
Enabled by default
Name the channel with a specified
channel number
info-center channel
channel-number name
channel-name
Optional
See
for default channel
names.
Configure the channel through
which system information can be
output to a monitor terminal
info-center monitor channel
{ channel-number | channel-name }
Optional
By default, system information is
output to the monitor terminal
through channel 1 (known as
monitor).
Configure the output rules of the
system information
info-center source
{ module-name | default } channel
{ channel-number | channel-name }
[ debug { level severity | state
state } * | log { level severity | state
state } * | trap { level severity |
state state } * ] *
Optional
See
Configure the format of the time
stamp
info-center timestamp
{ debugging | log | trap } { boot |
date | none }
Optional
By default, the time stamp format
for log, trap and debugging
information is date.
Enabling the display of system information on a monitor terminal
After setting to output system information to a monitor terminal, you need to enable the associated
display function in order to display the output information on the monitor terminal.