Rack-mounting, Installation tools, Installation accessories – H3C Technologies H3C MSR 3600 User Manual
Page 13
5
•
Install a special lightning arrester at the input end of outdoor signal lines (for example, E1/T1 line)
to which interface modules of the router are connected to enhance the lightning protection
capability.
Rack-mounting
Before mounting the router in a standard 19-inch rack, adhere to the following requirements:
•
The rack is equipped with a good ventilation system.
•
The rack is sturdy enough to support the router and its accessories.
•
For heat dissipation and device maintenance, make sure the front and rear of the rack are at least
0.8 m (2.62 ft) away from walls or other devices, and the headroom in the equipment room is no
less than 3 m (9.84 ft).
Installation tools
Installation accessories
Cage nut
(user-supplied)
Grounding cable
Rubber feet
(provided)
Cable tie
(user-supplied)
M6 screw
(user-supplied)
Front mounting brackets (provided)
M4 countersunk-head screw
(provided)
MSR 36-10/36-20/
3600-28/3600-51 MSR 36-40
MSR 36-60
Rear mounting brackets (provided)
Load-bearding screw
(provided with MSR 36-10/36-20/
36-40/36-60
)
MSR 36-10/36-20/
36-40/36-60
Bail latch
(provided with MSR3600-28)