Cooling system, Esd prevention – H3C Technologies H3C MSR 3600 User Manual

Page 11

background image

3

Cooling system

The MSR 36-10/36-20/3600-28/3600-51 router adopts left to right airflow for heat dissipation, and the

MSR 36-40/36-60 router adopts left to rear airflow for heat dissipation.

Figure 1 Airflow through the chassis (MSR 36-10/36-20/3600-28/3600-51)

Figure 2 Airflow through the chassis (MSR 36-40/36-60)

To ensure good ventilation, the following requirements must be met:

The air inlet and outlet vents are not blocked, and leave at least 10 cm (3.94 in) of clearance.

The installation site has a good cooling system.

ESD prevention

CAUTION:

Check the resistance of the ESD wrist strap for safety. The resistance reading should be in the range of 1
to 10 megohm (Mohm) between human body and the ground.