87
-
Event Description:
Event ID
Event Description
Description
[GK]: [xxx.xxx.xxx.xxx:xxxx] not
found or registered failure
Failed to register to H323
Gatekeeper
8003
[SIP Register]:
[xxx.xxx.xxx.xxx:xxxx] not found or
registered failure
Failed to registered to SIP
Registrater Server
8700
TRUNK ALARM: TrunkId=x,
Comment='', LOS=1, LOF=0, RAI=0,
AIS=0, RAI_CRC=0
Disconnect to PSTN
8702 BOARD
x
TRUNK(S)
FOUND Board x Trunk(s) found
8703
[0]: evt: D CHANNEL STATUS:
runkId=3, Status=1, Comment='',
LOS=14, LOF=0, RAI=108,
AIS=145, RAI_CRC=-1
D Channel and Trunk ID (ID: 0)
not available
9500
Gateway application started
VoIP Gateway program start
9500
AAA Mgr application started
AAA Manager program start
9500
TelnSvr application started
Telnet Server program start
9501
VoIP Board (0) started
Interface (ID:0) start
9502
H323 (SIP) stack started
H323 (SIP) stack start
H323 GK [xxx.xxx.xxx.xxx:xxxx]
found & registered
Registered to H323 Gatekeeper
9503
[SIP Register]: [xxx.xxx.xxx.xxxx]
Found & Registered.
Registered to SIP Registrater
Server
9504
PSTN trunk (0) alarm clear
Connect to PSTN
9505
[0]: evt: D CHANNEL STATUS:
TrunkId=3, Status=0, Comment='',
LOS=29, LOF=67, RAI=31, AIS=1,
RAI_CRC=-1
D Channel and Trunk ID (ID:0)
available
9600
SNTP client application started
Failed / Success to connect
SNTP server
Debug Info
Start Path: Click “Monitor>Debug Info”
Figure 9.5-1