beautypg.com

14 0x6062 position_demand_value, 15 0x6064 position_actual_value, 16 0x60f4 following_error_actual_value – Emerson SM-ETHERCAT 0471-0128-02 User Manual

Page 38

background image

38

SM-EtherCAT User Guide

www.controltechniques.com

Issue Number: 2

Table 7.26 lists the objects that are supported:

7.3.14 0x6062 Position_demand_value

This read only object is used to provide the currently demanded position value. The
value is given in user defined position units.

7.3.15 0x6064 Position_actual_value

This read only object provides the actual value of the position feedback device. The
value is given in internal units.

7.3.16 0x60F4 Following_error_actual_value

This read only object provides the actual value of the following error. The value is given
in user-defined position units.

Table 7.26 Basic position control supported objects

Index

Name

0x6062

position_demand_value

0x6064

position_actual_value

0x6065

following_error_window

0x6067

position_window

0x60F4

following_error_actual_value

0x60FB

position_control_parameter_set

Table 7.27 Position_demand_value

0x6062

Position_demand_value

Access: RO

Range: 0 to 0xFFFFFFFF

Size: Unsigned 32

Unit: N/A

Default:

N/A

Description:

Used to provide the currently demanded position value.

Table 7.28 Position_actual_value

0x6064

Position_actual_value

Access: RO

Range: 0 to 0xFFFFFFFF

Size: Unsigned 32

Unit: N/A

Default:

N/A

Description:

This read only object provides the actual value of the position feedback device. The value
is given in internal units.

Table 7.29 Following_error actual_value

0x60F4

Following_error actual_value

Access: RO

Range: 0 to 0xFFFFFFFF

Size: Unsigned 32

Unit: N/A

Default:

N/A

Description:

This read only object provides the actual value of the following error.