Example 4 - emif and escon directors used, Cpu2, Cpu1 switch 04 – Visara CCA-3074 Planning Guide User Manual
Page 50: Cca-3074, Second cpu definitions
![background image](https://www.manualsdir.com/files/808686/content/doc050.png)
Chapter 4. IOCDS Sample Definitions
4-6
707159-002
EXAMPLE 4 - EMIF and ESCON Directors Used
LPARS on two different CPUs are connected through an ESCON
director to a single CCA-3074 over a single ESCON interface. Users on
the CCA-3074 can have sessions on any or all of the 4 LPARs shown.
Up to 16 LPARs can be supported through the single ESCON interface
to the CCA-3074.
First CPU Definitions:
RESOURCE PARTITION=((LPAR390,1),(TEST1,2))
CHPID PATH=(1F),PARTITION=((LPAR390,TEST1)),SWITCH=04,TYPE=CNC,SHARED
CNTLUNIT CUNUMBR=1E00,PATH=1F,UNITADD=(00,5),UNIT=3174,CUADD=0,LINK=C4
IODEVICE CUNUMBR=IE00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)
CNTLUNIT CUNUMBR=1F00,PATH=1F,UNITADD=(00,5),UNIT=3174,CUADD=1,LINK=C4
IODEVICE CUNUMBR=1F00,ADDRESS=(1200,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)
Second CPU Definitions:
RESOURCE PARTITION=((LPAR390B,3),(TEST2,4))
CHPID PATH=(43),PARTITION=((LPAR390B,TEST2)),SWITCH=04,TYPE=CNC,SHARED
CNTLUNIT CUNUMBR=1195,PATH=43,UNITADD=(00,5),UNIT=3174,CUADD=5,LINK=C4
IODEVICE CUNUMBR=1195,ADDRESS=(1E00,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST2)
CNTLUNIT CUNUMBR=2144,PATH=43,UNITADD=(00,5),UNIT=3174,CUADD=1,LINK=C4
IODEVICE CUNUMBR=2144,ADDRESS=(700,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)
LPAR390B
TEST2
43
MIF
CPU2
LPAR390
TEST1
1F
MIF
CPU1
SWITCH 04
C4
A1
19
CCA-3074