EXAMPLE 4 - EMIF and ESCON Directors Used

LPARS on two different CPUs are connected through an ESCON
director to a single CCA-3074 over a single ESCON interface. Users on
the CCA-3074 can have sessions on any or all of the 4 LPARs shown.
Up to 16 LPARs can be supported through the single ESCON interface
to the CCA-3074.

First CPU Definitions:

RESOURCE PARTITION=((LPAR390,1),(TEST1,2))

CHPID PATH=(1F),PARTITION=((LPAR390,TEST1)),SWITCH=04,TYPE=CNC,SHARED

CNTLUNIT CUNUMBR=1E00,PATH=1F,UNITADD=(00,5),UNIT=3174,CUADD=0,LINK=C4

IODEVICE CUNUMBR=IE00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)

CNTLUNIT CUNUMBR=1F00,PATH=1F,UNITADD=(00,5),UNIT=3174,CUADD=1,LINK=C4

IODEVICE CUNUMBR=1F00,ADDRESS=(1200,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)

Second CPU Definitions:

RESOURCE PARTITION=((LPAR390B,3),(TEST2,4))

CHPID PATH=(43),PARTITION=((LPAR390B,TEST2)),SWITCH=04,TYPE=CNC,SHARED

CNTLUNIT CUNUMBR=1195,PATH=43,UNITADD=(00,5),UNIT=3174,CUADD=5,LINK=C4

IODEVICE CUNUMBR=1195,ADDRESS=(1E00,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST2)

CNTLUNIT CUNUMBR=2144,PATH=43,UNITADD=(00,5),UNIT=3174,CUADD=1,LINK=C4

IODEVICE CUNUMBR=2144,ADDRESS=(700,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)

LPAR390B

TEST2

43

MIF

CPU2

LPAR390

TEST1

1F

MIF

CPU1

SWITCH 04

C4

A1

19