Chapter 4. IOCDS Sample Definitions
4-2
707159-002
EXAMPLE 1 - Typical 3174 Replacement (ESCON)
This first example shows the replacement of two ESCON attached 3174s with a single
CCA-3074 (also on ESCON). The first definitions shown are used to define the two
3174-22L. The second set of definitions is used to connect the CCA-3074.
3174 Definitions
RESOURCE PARTITION=((LPAR390,1),(TEST1,2)
CHPID PATH=(1F),TYPE=CNC,PARTITION=(LPAR390)
CHPID PATH=(1E),TYPE=CNC,PARTITION=(TEST1)
CNTLUNIT CUNUMBR=IFOO,PATH=1F,UNITADD=((00,5)),UNIT=3174
CNTLUNIT CUNUMBR=IEOO,PATH=1E,UNITADD=((00,5)),UNIT=3174
IODEVICE CUNUMBR=IF00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)
IODEVICE CUNUMBR=IE00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)
CCA-3074 Definitions
RESOURCE PARTITION=((LPAR390,1),(TEST1,2))
CHPID PATH=(1E),TYPE=CNC,SWITCH=01,SHARED
CNTLUNIT CUNUMBR=IEOO,PATH=1E,UNITADD=((00,5)),UNIT=3174
CNTLUNIT CUNUMBR=IFOO,PATH=1E,UNITADD=((00,5)),UNIT=3174
IODEVICE CUNUMBR=IE00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)
IODEVICE CUNUMBR=IF00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)
LPAR390
TEST1
1E
1F
LPAR390
TEST1
1E
EMIF
Before