beautypg.com

Cca-3074 definitions – Visara CCA-3074 Planning Guide User Manual

Page 46

background image

Chapter 4. IOCDS Sample Definitions

4-2

707159-002

EXAMPLE 1 - Typical 3174 Replacement (ESCON)

This first example shows the replacement of two ESCON attached 3174s with a single
CCA-3074 (also on ESCON). The first definitions shown are used to define the two
3174-22L. The second set of definitions is used to connect the CCA-3074.

3174 Definitions

RESOURCE PARTITION=((LPAR390,1),(TEST1,2)

CHPID PATH=(1F),TYPE=CNC,PARTITION=(LPAR390)

CHPID PATH=(1E),TYPE=CNC,PARTITION=(TEST1)

CNTLUNIT CUNUMBR=IFOO,PATH=1F,UNITADD=((00,5)),UNIT=3174

CNTLUNIT CUNUMBR=IEOO,PATH=1E,UNITADD=((00,5)),UNIT=3174

IODEVICE CUNUMBR=IF00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)

IODEVICE CUNUMBR=IE00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)

CCA-3074 Definitions

RESOURCE PARTITION=((LPAR390,1),(TEST1,2))

CHPID PATH=(1E),TYPE=CNC,SWITCH=01,SHARED

CNTLUNIT CUNUMBR=IEOO,PATH=1E,UNITADD=((00,5)),UNIT=3174

CNTLUNIT CUNUMBR=IFOO,PATH=1E,UNITADD=((00,5)),UNIT=3174

IODEVICE CUNUMBR=IE00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)

IODEVICE CUNUMBR=IF00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)

LPAR390

TEST1

1E

1F

LPAR390

TEST1

1E

EMIF

Before

After