Parameter Definition Cross Reference Chart

The following chart and notes can be used to help show the
corresponding configuration parameters between the IOCDS
definitions, HCD definitions, and the CCA-3074 configuration.

IOCDS HCD CCA-3074

MACRO Parameter

Panel

Parameter Panel

Parameter

CNTLUNIT CUADD Change

Control

Unit Definition

Logical Address

Update

ESCON/FICON

CUs

CUADD

IODEVICE

CNTLUNIT

UNITADD Define

Device/Processor

Unit Address

Update

ESCON/FICON

CUs

Low

Address

IODEVICE

ADDRESS

Add Device

Number of Devices

Update

ESCON/FICON

CUs

High

Address

CHPID Update

CHPID

Access and

Candidate List

Access List = Yes

IODEVICE

PARTITION

Define Device

Candidate List

Partition/Reachable

Update

ESCON/FICON

CUs

LPAR

Number

CHPID SWITCH Add

Channel

Path

Dynamic Switch

ID or Entry Switch

ID

N/A N/A

CNTLUNIT LINK Change

Control

Unit Definition

Link Address

N/A

N/A

CNTLUNIT Change

Control

Unit Defintion

Control Unit

Number

IODEVICE

CUNUMBR

Add Device

Connected to CUs

N/A N/A

IODEVICE

UNIT

Add Device

Device Type

Update

ESCON/FICON

CUS

Protocol

Notes:

1. Note that the UNITADD parameter of the IODEVICE macro

must correspond to one or more of the range of addresses
defined in the UNITADD parameter of the CNTLUNIT
macro.

2. Each address within the range defined by the UNITADD

parameter of the CNTLUNIT macro that has an associated
IODEVICE definition should have a Subchannel definition on
the CCA-3074

.