Parameter definition cross reference chart – Visara CCA-3074 Planning Guide User Manual
Page 28

Chapter 2. Planning for Your Installation
2-14
707159-002
Parameter Definition Cross Reference Chart
The following chart and notes can be used to help show the
corresponding configuration parameters between the IOCDS
definitions, HCD definitions, and the CCA-3074 configuration.
IOCDS HCD CCA-3074
MACRO Parameter
Panel
Parameter Panel
Parameter
CNTLUNIT CUADD Change
Control
Unit Definition
Logical Address
Update
ESCON/FICON
CUs
CUADD
IODEVICE
CNTLUNIT
UNITADD Define
Device/Processor
Unit Address
Update
ESCON/FICON
CUs
Low
Address
IODEVICE
ADDRESS
Add Device
Number of Devices
Update
ESCON/FICON
CUs
High
Address
CHPID Update
CHPID
Access and
Candidate List
Access List = Yes
IODEVICE
PARTITION
Define Device
Candidate List
Partition/Reachable
Update
ESCON/FICON
CUs
LPAR
Number
CHPID SWITCH Add
Channel
Path
Dynamic Switch
ID or Entry Switch
ID
N/A N/A
CNTLUNIT LINK Change
Control
Unit Definition
Link Address
N/A
N/A
CNTLUNIT Change
Control
Unit Defintion
Control Unit
Number
IODEVICE
CUNUMBR
Add Device
Connected to CUs
N/A N/A
IODEVICE
UNIT
Add Device
Device Type
Update
ESCON/FICON
CUS
Protocol
Notes:
1. Note that the UNITADD parameter of the IODEVICE macro
must correspond to one or more of the range of addresses
defined in the UNITADD parameter of the CNTLUNIT
macro.
2. Each address within the range defined by the UNITADD
parameter of the CNTLUNIT macro that has an associated
IODEVICE definition should have a Subchannel definition on
the CCA-3074
.