Example 3 – device candidate list not used – Visara CCA-3074 Planning Guide User Manual
Page 49
CCA-3074 Planning
707159-002
4-5
EXAMPLE 3 – Device Candidate List not Used
A single CNTLUNIT and IODEVICE definition is used to define consoles on all four
LPARS, by intentionally not using the Device Candidate list. This method makes use of
the same CUNUMBR and IODEVICE numbers in each LPAR that shares the CHPID.
A separate CU definition is still required on the CCA-3074 to direct each connection to
the correct LPAR.
RESOURCE PARTITION=((LPAR390,1),(LPARZOS,2),(PROD3,3),(TEST1,4))
CHPID PATH=(72),PARTITION=((LPAR390,LPARZOS,PROD3,TEST1)),TYPE=CNC,SHARED
CNTLUNIT CUNUMBR=985,PATH=72,UNITADD=((20,16)),UNIT=3174,CUADD=3
IODEVICE CUNUMBR=985,ADDRESS=(800,16),UNIT=3270-X,UNITADD=20
Notes:
1. Since there is no PARTITION parameter displayed in the IODEVICE statement,
the IODEVICE and CNTLUNIT definitions are valid in all partitions sharing the
path. The attached CCA-3074 must have a separate CU defined to communicate
with each of the four partitions.
EMIF
LPAR390
PROD3
LPARZOS
TEST1
72