Verilink WANsuite 6x30 (34-00315.B) Product Manual User Manual
Page 45

W e b S e r v e r I n t e r f a c e
3-17
Alarm Profile Details Screen
Clicking on the “Alarm Profile Details” button displays the screen shown in
Figure 3.14. The table on this screen lets you create/delete the associated
entry in this table (profile name), and configure the alarm threshold values to
be used for the selected segment endpoint.
Figure 3.14
Alarm Profile Details Screen
P rofile N a m e
Displays the unique index associated with this Endpoint Alarm profile. A new
Alarm Profile can be created by entering a unique name for the profile in this
field and then, after configuring the desired alarm thresholds, clicking on the
“Submit” button.
L oo p A tten u atio n
Sets the loop attenuation alarm threshold. If the current value reaches or drops
below this threshold, a crossing trap is generated.
S N R M argin
Sets the Signal-to-Noise Ratio margin alarm threshold. When the current SNR
value reaches or drops below this threshold, a crossing trap is generated.
E S
Sets the threshold for the number of Errored Seconds within any given 15-
minute performance data collection interval. If the value of ES in a particular
15-minute collection interval reaches/ exceeds this value, a trap is generated.
One trap will be sent per interval per endpoint.
S E S
Sets the threshold for the number of Severely Errored Seconds within any
given 15-minute performance data collection interval. If the value of SES in a
particular 15-minute collection interval reaches/exceeds this value, a trap is
generated. One trap will be sent per interval per endpoint.
C R C
Sets the threshold for the number of Cyclic Redundancy Check anomalies
within any given 15-minute performance data collection interval. If the value
of CRC anomalies in a particular 15-minute collection interval reaches/
exceeds this value, a trap is generated. One trap will be sent per interval per
endpoint.
L O S W S
Sets the threshold for the number of Loss of Sync Word Seconds within any
given 15-minute performance data collection interval. If the value of LOSW