17600 – system data, 17601:17620 – card data – Thinklogical Router Interfaces User Manual
Page 21

17600 – System Data
System data consists of 28 bytes. The first two bytes have the current alarm contact
settings (big-endian). Each bit corresponds to a contact. Bit 0 (lsb) of byte 1 is the bit for
the Power Supply 1 alarm, and bit 7 (msb) is the bit for the 'any' alarm. The next five bytes
are for the installed card inventory. A '0' bit means the card is installed and a '1' bit means
the card is removed. The other bytes are for internal use.
17601:17620 – Card Data
Each I/O card in the VxRouter has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:
•
16 bytes, internal use
•
2 bytes, card type
◦
0xff, 0xff
missing
◦
0x00, 0x62
VX640 I/O card (bits 7-4, ignore bits 3-0)
•
signed 16-bits, card temperature (little-endian, bits 15-7)
◦
example: 0x80 0x1d -> 0x1d80 -> 29.5°C
•
5 bytes, internal use
•
SFP data, 256 bytes per SFP, 16 SFPs per card
◦
128 bytes, SFP ID data
◦
128 bytes, SFP diagnostic data
Nov 3, 2014
Router Interfaces: VX640
21/25
Table 7: Vx640Video System Data
Alarms
Inventory
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Bit
0
1
2
3
4
5
6
0
Alarm 9
Alarm 1
Card 17
Card 1
Card 18
Card 2
Switch 1
1
Alarm 10
Alarm 2
Card 19
Card 3
Card 20
Card 4
Switch 1
2
Alarm 3
Card 21
Card 5
Card 22
Card 6
Switch 3
3
Alarm 4
Card 23
Card 7
Card 24
Card 8
Switch 4
4
Alarm 5
Card 25
Card 9
Card 26
Card 10
Switch 5
5
Alarm 6
Card 27
Card 11
Card 28
Card 12
Switch 6
6
Alarm 7
Card 29
Card 13
Card 30
Card 14
Switch 7
7
Alarm 8
Card 31
Card 15
Card 32
Card 16
Switch 8