17600 – system data, 17601:17636 – card data – Thinklogical Router Interfaces User Manual
Page 17
17600 – System Data
•
System data consists of 18 bytes. The first two bytes have the current alarm contact
settings (big-endian). Each bit corresponds to a contact. Bit 0 (lsb) of byte 1 is the bit for
the Power Supply 1 alarm, and bit 7 (msb) is the bit for the 'any' alarm. The next five bytes
are for the installed card inventory. A '0' bit means the card is installed and a '1' bit means
the card is removed. The other bytes are for internal use.
17601:17636 – Card Data
•
Each I/O card in the HDxRouter has an associated TCP port. Card 1 uses port 17601, card
2 uses 17602, and so on. The data is formatted as follows:
•
12 bytes, internal use
•
1 byte, card type
◦
0xff missing
◦
0x01 downstream
•
SFP data, 256 bytes per SFP, 16 SFPs per card
◦
128 bytes, SFP ID data
◦
128 bytes, SFP diagnostic data
Nov 3, 2014
Router Interfaces: HX576
17/25
Table 5: Hx576 System Data
Alarms
Inventory
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Bit
0
1
2
3
4
5
6
0
Alarm 9
Alarm 1
Card 1
Card 9
Card 26
Card 14
Card 31
1
Alarm 10
Alarm 2
Card 2
Card 19
Card 27
Card 15
Card 32
2
Alarm 3
Card 3
Card 20
Card 16
Card 33
3
Alarm 4
Card 4
Card 21
Crad 17
Card 34
4
Alarm 5
Card 5
Card 22
Card 10
Card 18
Card 35
5
Alarm 6
Card 6
Card 23
Card 11
Card 28
Card 36
6
Alarm 7
Card 7
Card 24
Card 12
Card 29
7
Alarm 8
Card 8
Card 25
Card 13
Card 30