MX48

17564 – Switch Connection Status Broadcast

32-bits, MxRouter's primary IP address

16-bits, 0 for the Upper (only) router chassis

16-bits, first port number in the list (list starts from 1, not 0)

16-bits, last port number in the list

N * 16-bits, the input port that is connected to output port X, zero means the port is NOT
connected

Example:

c0 a8 0d 19 00 00 00 01 00 30 00 11 00 12…

IP address = 192.168.13.25
Chassis = 0
First Port number = 1
Last Port number = 48 (

0x0030)

Output 1 is connected to input 17 (

0x0011)

Output 2 is connected to input 18 (

0x0012)

17565 – Port Settings (localhost only)

48 sets of the following data:

(8 bits) output level

0 is off

(8 bits) input level

(8 bits) connected to input port number, starting from 0

A 'C' data structure for this would be:

struct s_block {

unsigned char output_level;

unsigned char input_level;
unsigned char connectedTo;

} data_block [48];

17566 – Hardware Status

Reserved for future use.