17600 – system data, 17601:17640 – card data – Thinklogical Router Interfaces User Manual
Page 13

17600 – System Data
System data consists of 18 bytes. The first two bytes have the current alarm contact
settings (big-endian). Each bit corresponds to a contact. Bit 0 of byte 1 is the bit for the
Power Supply 1 alarm, and bit 1 of byte 0 is the bit for the 'any' alarm. The next five bytes
are for the installed card inventory. A '0' bit means the card is installed and a '1' bit means
the card is removed. The other bytes are for internal use.
17601:17640 – Card Data
Each I/O card in the VxRouter has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:
•
12 bytes, internal use
•
1 byte, card type
◦
0xff
missing
◦
0x02
installed
•
SFP data, 256 bytes per SFP, 16 SFPs per card
◦
128 bytes, SFP ID data
◦
128 bytes, SFP diagnostic data
Nov 3, 2014
Router Interfaces: VX320
13/25
Table 3: Vx320 System Data
Alarms
Inventory
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Bit
0
1
2
3
4
5
6
0
Alarm 9
Alarm 1
Upper Card 1
Upper Card 9
Upper Card 17 Lower Card 5
Lower Card 13
1
Alarm 10
Alarm 2
Upper Card 2
Upper Card 10 Upper Card 18 Lower Card 6
Lower Card 14
2
Alarm 3
Upper Card 3
Upper Card 11 Upper Card 19 Lower Card 7
Lower Card 15
3
Alarm 4
Upper Card 4
Upper Card 12 Upper Card 20 Lower Card 8
Lower Card 16
4
Alarm 5
Upper Card 5
Upper Card 13 Lower Card 1
Lower Card 9
Lower Card 17
5
Alarm 6
Upper Card 6
Upper Card 14 Lower Card 2
Lower Card 10 Lower Card 18
6
Alarm 7
Upper Card 7
Upper Card 15 Lower Card 3
Lower Card 11 Lower Card 19
7
Alarm 8
Upper Card 8
Upper Card 16 Lower Card 4
Lower Card 12 Lower Card 20