beautypg.com

17600 – system data, 17601:17603 – card data – Thinklogical Router Interfaces User Manual

Page 19

background image

17600 – System Data

System data consists of 6 bytes. The first byte has the current alarm contact settings. Each
bit corresponds to a contact. Bit 0 (lsb) is the bit for the Power Supply alarm, and bit 3 is
the bit for the 'any' alarm. The next byte is for the installed card inventory. A '0' bit means
the card is installed and a '1' bit means the card is removed. The other bytes are for
internal use.

17601:17603 – Card Data

Each I/O card in the router has an associated TCP port. Card 1 uses port 17601, card 2 uses
17602, and so on. The data is formatted as follows:

6 bytes, internal use

1 byte, card type

0xff

missing

0x02

normal

0x05

reclocked

SFP data, 256 bytes per SFP, 16 SFPs per card

128 bytes, SFP ID data

128 bytes, SFP diagnostic data

Nov 3, 2014

Router Interfaces: MX48

19/25

Table 6: MX48 System Data

Alarms

Inventory

Byte

Byte

Bit

0

1

0

Alarm 1

Card 1

1

Alarm 2

Card 2

2

Alarm 3

Card 3

3

Alarm 4

4

5

6
7