beautypg.com

17600 – system data, 17601:17620 – card data – Thinklogical Router Interfaces User Manual

Page 15

background image

17600 – System Data

System data consists of 18 bytes. The first two bytes have the current alarm contact
settings (big-endian). Each bit corresponds to a contact. Bit 0 (lsb) of byte 1 is the bit for
the Power Supply 1 alarm, and bit 7 (msb) is the bit for the 'any' alarm. The next three
bytes are for the installed card inventory. A '0' bit means the card is installed and a '1' bit
means the card is removed. The other bytes are for internal use.

17601:17620 – Card Data

Each I/O card in the VxRouter has an associated TCP port. Card 1 uses port 17601, card 2
uses 17602, and so on. The data is formatted as follows:

12 bytes, internal use

1 byte, card type

0xff

missing

0x01

downstream

SFP data, 256 bytes per SFP, 16 SFPs per card

128 bytes, SFP ID data

128 bytes, SFP diagnostic data

Nov 3, 2014

Router Interfaces: VX320Video

15/25

Table 4: Vx320Video System Data

Alarms

Inventory

Byte

Byte

Byte

Byte

Byte

Bit

0

1

2

3

4

0

Alarm 1

Card 1

Card 9

Card 17

1

Alarm 2

Card 2

Card 10

Card 18

2

Alarm 3

Card 3

Card 11

Card 19

3

Alarm 4

Card 4

Card 12

Card 20

4

Alarm 5

Card 5

Card 13

5

Alarm 6

Card 6

Card 14

6

Alarm 7

Card 7

Card 15

7

Alarm 8

Card 8

Card 16