beautypg.com

Hx576, 17564 – switch connection status broadcast, 17565 – port settings (localhost only) – Thinklogical Router Interfaces User Manual

Page 16: 17566 – hardware status

background image

HX576

17564 – Switch Connection Status Broadcast

32-bits, HDxRouter's primary IP address

16-bits, 0 for the Upper (only) HDxRouter chassis

16-bits, first port number in the list (list starts from 1, not 0)

16-bits, last port number in the list

N * 16-bits, the input port that is connected to output port X, zero means the port is NOT
connected

Example:

c0 a8 0d 19 00 00 00 01 02 40 00 11 00 12…

IP address = 192.168.13.25
Chassis = 0
First Port number = 1
Last Port number = 576 (

0x0240)

Output 1 is connected to input 17 (

0x0011)

Output 2 is connected to input 18 (

0x0012)

17565 – Port Settings (localhost only)

576 sets of the following data:

(8 bits) output level

0 is off

(8 bits) input level

(16 bits) connected to input port number, starting from 0, big-endian format

A 'C' data structure for this would be:

struct s_block {

unsigned char output_level;
unsigned char input_level;
unsigned short

connectedTo; /* assumes a short is 16 bits */

} data_block [576];

17566 – Hardware Status

Reserved for future use.

Nov 3, 2014

Router Interfaces: HX576