Ssignments – Super Systems 9130 Series User Manual
Page 66

Series 9130 Operations Manual Rev -
65
[A]CarbPro v3.5
[T]9200 LP3
SSi M4L
User 2
[A]CarbPro v3.0
9100 LP2
SSi X5/Timer
User 3
CarbPC
Eurotherm 2704 LP1
SSi SPUD
User 4
[A]9200 LP1
Eurotherm 2704 LP2
SSi AIB3
User 5
IR Base
Eurotherm 2704 LP3
SSi H2 Cell
User 6
MGA
VC Base 1
Flow Meter Short
User 7
SSi 7EK
VC Base 2
SSi O2 Remote
User 8
[T]Yokogawa 750
VC Base 3
SSi Dual Motor Board User 9
[T]Honeywell UDC3300
VC Base 4
SSi AC E
User 10
[T]Dualpro LP1 Modbus
AIPC
Yokogawa 750E
User 11
[T]Dualpro LP2 Modbus
SSi 7SL
Mod Mux
User 12
[T]Dualpro LP1 MMI
AEC Flow Board
Dualpro E Modbus
User 13
[T]Dualpro LP2 MMI
UMC800 LP1
Dualpro E MMI
User 14
[T]Eurotherm 2404
SSi Quad AO1
Carbpro E v3.5
User 15
User 16
Address
This value allows the user to select the address that corresponds with the controller selected, with a range
of 0 to 249.
Port
The options for this field are: Slave 1, Slave 2, RS-232, IP Address 1, IP Address 2, IP Address 3, IP Address
4, Passive, or Slave 3/RS-232.
Slave 1 – terminals 5(-), 6(+)
Slave 2 – terminals 22(+), 23(-)
RS-232
Zone Assignments
A zone assignment on the 9130 vacuum
controller allows the recipe programs to
change setpoints on all slave instruments of
a multi-zone furnace (up to 10 zones).
*Only used when running recipes
*Slave Instrument Setup must be configured
prior to Zone Assignment setup
** Temperature zones link instruments to Temperature Setpoints
Assignments
The zone assignment number, with a choice of Assignment 1 through Assignment 10.
Temp Instrument
The temperature instrument number, with a choice of: Loop 1, and Instrument 1 – Instrument 25.
Temp Zone Number
The zone within which the temperature setpoint change is desired, with a range of 0 to 10.
Default Zone Offset, temp
This is the default zone offset for temperature, with a range of –32000 to 32000.