beautypg.com

Sundance SMT384 User Manual

Page 36

background image

Version 1.4

Page 36 of 47

SMT384 User Manual


AD9510 Register 0 – 0x30.
For more details, refer to AD9510 datasheet.

AD9510 Register 0 – 0x30

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

1

Not Used

Default

‘00000000’

0

SDO

Inactive

LSB First

Soft Reset

Long Inst.

Not Used

Default

‘0’ ‘0’ ‘0’ ‘1’

‘0000’


AD9510 Register 1 – 0x31.
For more details, refer to AD9510 datasheet.

AD9510 Register 1 – 0x31

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

1

Not Used

Default

‘00000000’

0

Not Used

Default

‘00000000’


AD9510 Register 2 – 0x32.
For more details, refer to AD9510 datasheet.

AD9510 Register 2 – 0x32

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

1

Not Used

13-bit B Counter (12…8)

Default

‘000’ ‘00000’

0

Not Used

6-bit A Counter

Default

‘00’ ‘000000’


AD9510 Register 3 – 0x33.
For more details, refer to AD9510 datasheet.

AD9510 Register 3 – 0x33

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

1

Not Used

LOR Lock_Del

Not Used

LOR Enable

Not Used

Default

‘0’ ‘00’

‘00’ ‘0’ ‘00’

0

13-bit B Counter (7…0)

Default

‘00000000’