beautypg.com

Sierra Video Ponderosa 3G Series Routing Switcher User Manual

Page 38

background image

SIERRA VIDEO

32

GPI

The 25 pin D connector on the rear of the Master CPU frame provides relay contacts under
software control that can be used to indicate a failure of router frame power supplies and fans.

The female 25 pin D connector on the rear of the CPU frame provides access to 5 relay contact
sets (GPI-out 0-4). These contact sets are used to indicate failures in the router frames.

The female 25 pin D connector also provides for “GPI inputs” where an external contact closure
can cause an “event”. GPI inputs need to be grounded to initiate event.

GPI setting are described in the chart below;

* Contact the SVS Factory for “Future Use” updates.

Note:

All relay contacts are floating relative to any ground in the router or CPU frame. No relay contact should
be more than 150VRMS from CPU frame ground. Relay contact ratings are 0.5A @ 125VAC, 2A @
30VDC.

Pin #

Connection

Alarm Description

1

GPI-4 out N/O

* Future Use

2

GPI-4 out Common

3

N/C Not

Used

4

GPI-2 out N/O

Failure- Fan Power Supply # 1

5

GPI-2 out Common

6

N/C Not

Used

7

GPI-0 out N/O

Failure- Power Supply # 1

8

GPI-0 out Common

9

GPI-4 in

* Future Use

10

GPI-3 in

* Future Use

11

GPI-2 in

* Future Use

12

GPI-1 in

* Future Use

13

GPI-0 in

Close All GPI- out Contacts

14

N/C Not

Used

15

GPI-3 out N/O

Failure- Fan Power Supply # 2

16

GPI-3 out Common

17

N/C Not

Used

18

GPI-1 out N/O

Failure- Power Supply # 2

19

GPI-1 out Common

20

N/C Not

Used

21

GND

Ground Connection for GPI in

22

GND

Ground Connection for GPI in

23

GND

Ground Connection for GPI in

24

GND

Ground Connection for GPI in

25

GND

Ground Connection for GPI in