Installation, Introduction, Rack mounting – Sierra Video Ponderosa 3G Series Routing Switcher User Manual
Page 17: Chapter
![background image](https://www.manualsdir.com/files/804414/content/doc017.png)
SIERRA VIDEO
11
Installation
Introduction
Installation procedures are similar for all frames covered within this manual. Exceptions, if any,
have been noted in each of the following paragraphs.
Rack Mounting
Carefully inspect the frame to ensure that there has been no shipping damage. Make sure all
shipping material is removed from the router frame.
Each of the routing switchers described in this manual can be rack mounted in a standard 19"
(RU) EIA rack assembly and includes rack "ears" at the ends of the front of the frames. None of
the switcher models require spacing above or below the unit for ventilation. If ample space exists,
a 1RU spacing gap is recommended.
To rack mount any of the routing switchers, simply place the unit's rack ears against the rack rails
of the rack, and insert proper rack screws through each of the holes in the rack ears. Always rack
mount the routing switcher prior to plugging the unit into a power receptacle or attaching any
cables.
Important:
Rear mounting brackets must be installed prior to installation of the router into a
rack. The rear mounting brackets are contained in the accessory kit supplied with your router.
CAUTION!
The operating temperature range of the Ponderosa series router is 0 to 40 °C. Do not exceed the
maximum (40 °C) or minimum (0 °C) operating temperature.
Rear mounting brackets must be installed prior to installation of the router into a rack. The rear mounting
brackets are contained in the accessory kit supplied with your router.
If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than the room ambient temperature. Therefore, consideration should be
given to installing the equipment in an environment compatible with the manufacturer’s maximum rated
ambient temperature (TMRA).
Installation of the equipment in a rack should be such that the amount of air flow required for safe
operation of the equipment is not compromised.
Chapter
2
- Pro Series 64XL 1616 Series HD/SDI 3G Shasta HD Routing Switcher Shasta HD 88 HD Shasta HD 88 SDI 1601 Series HD/SDI Shasta HD Scanning Routing Switchers 1602 Series HD/SDI Shasta HD Routing Switchers 1602 Series HD/SDI Shasta HD Scanning Routing Switchers 1601 Series HD/SDI Dual Output Shasta HD Routing Switchers Pro XL Series 8 Pro XL Series 12 Alta Pro Series Tahoe 3232CAA Tahoe 32128V Lassen XL Series VS Lassen XL Series DE Lassen XL Series HD Lassen XL Series SDI Tahoe 3264VAA Tahoe Series 48 Tahoe Series 16 Tahoe Series 20 Shasta 88D Shasta 88E Shasta 1601D Shasta 1616D Tahoe Series 32 Shasta Series 16 Shasta Series 32 Pro XL Series 16 Pro XL Series 32 Viper Component Series Viper Composite Series