Selecting The Test Settings

14

Flash Test

Voltage = 2500Vac
Duration = 2 seconds
Pass level = below 2mA

Power/Leakage Test

Voltage = Supply voltage

Duration = 5 seconds

Power Pass level = Nominal >=4

Leakage Pass level = below 1mA



C: POWER CORD TEST

This test selection is for the testing of detachable power cords such
that used by computers & kettles etc. The standard test settings for
this selection are:

Earth Bond Test


Current = 100mA
Duration = 2 seconds
Pass level = below 0.5


Line Short to Case

Voltage = 40Vac

Duration = 2 seconds

Pass level = below 1mA


Flash Test

Voltage = 1250Vac
Duration = 2 seconds
Pass level = below 3mA