beautypg.com

Seaward 220 PrimeTest User Manual

Page 15

background image

Operating Instructions

Primetest 220

8

7.2 Insulation resistance measuring range (rotary

switch position , , IEC and M

.

Measuring Range Resolution

Accuracy Overload Protection

2M

0.01M

±2% ±2 digits

300 V AC/DC

20M

0.1M

±5% ±2 digits

300 V AC/DC

200M

1M

±10% ±2 digits

300 V AC/DC

Test voltage

500VDC at 1mA,
<750VDC for o/c

Test voltage accuracy

+20%, -0%

Test current

<2mA for s/c

The maximum number of insulation tests, with a duty
cycle specified by BS EN 61557-2 Section 6.7, is 2000
repetitions.

7.3 IEC lead test

The IEC lead test is a sequence of earth continuity
measurement (section 7.1) - insulation resistance
measurement (section 7.2) - Live/Neutral checks for o/c,
s/c and crossed conductors in the IEC lead.

Test voltage

9 VDC

Test duration

10 seconds

7.4 Touch current measurement

Measuring Range Resolution

Accuracy

Overload Protection

3.5mA

0.01mA ±10% ±2 digits (5° - 40°)

N/A

±15% ±2 digits (0° - 5°)

Test voltage

mains supply @ 230V -
15%/+10% @ 10A max

Frequency

50Hz ±1%

Test duration

2 seconds minimum

Frequency response

IEC 61010-1 Annex A.1

The test is disabled when phase-neutral (PN) or phase-
earth (PE) voltage is not at mains potential or a voltage of
40 V AC or greater exists between neutral-earth (NE).

PrimeTest 220 REV 1 5/12/05 1:52 pm Page 13