Model L1000 Laser Inspector
TM
Operator
’
s Guide
RJS, Minneapolis, MN
002-5568
28
8.1 Continuous and Multi-scan modes
In the Continuous Mode, an additional data analysis screen displays:
# Decodes 013/019
% Decodes 068%
There is a limit of 100 good scans in the Continuous Modeor 250 total scans—whichever
comes first. When a limit is reached, the unit automatically stops scanning.
In continuous mode the unit continues to attempt reads as long as the trigger is depressed.
When using this mode the beam may be moved around the symbol to provide extra analysis.
The analysis result is based on the average.
When multi-scans are selected the number of remaining scans needed to complete the
analysis is displayed:
*0192837465*
03 Scans Remain
After the last scan a double beep or chirp will signal completion of the scan. The resulting
analysis is an average of the scans.
13 good decodes out of
19 attempted reads
Percentage of good reads