5.2 Setup
Select Setup (from the Main Menu) to set various system parameters:
D/bility Warning
D
Select an ANSI decodability grade to use in your analysis (See Appendix G for an explana-
tion of the grades.)
A warning message will be produced for the selected grade or any lower grades:
B C D F NONE
Press Select to scroll the choices for warning threshold grade
Press Enter to initiate processing for that option
If NONE is selected, the decodability grade will not be used to trigger a warning message.
However, the decodability grade will be calculated and available for viewing.
The next selection allows selection from a range of UPC/EAN symbol magnifications:
UPC/EAN tol.
90 - 115% Mag.
The magnifications selections are:
(See Appendix D for an explanation of magnifications.)
80 - 89 % Mag
90 - 115 % Mag
116 - 150 % Mag
151 - 200 % Mag