DXP D1616 User Manual 67

connections is broken or joint is loose, you can replace the connecting

line.

3. Check if the output port is in accord with the controlled port.

4. If not belong to above three circumstances, maybe it is caused by host

internal fault, please send to professional for maintenance.

5If there is no display in LCD and no reaction for operation, please

check if the power input is good contacts.

6If the output image is disturbed, maybe the input/output devices

without good ground.

7If there is obvious electrostatic when drawing or inserting audio

and video interface, maybe the power ground without good ground,

please ground with the right way, otherwise, it will easily damage the

host and shorten the host life.

8 LCD display is normal, communication port has return code, but

no image output or no audio output:

 Maybe the AV interface is loose, you can just plug it tightly;

 Maybe it is short connection, you can just change it;

 Maybe wire is break, you can just change it.

9If matrix panel button, communication port can not be controlled,

maybe host internal is damaged, please send to professional for

maintenance.