8.

Trouble Analysis and Trouble Shooting

1. The installed software cannot be operated:

1.1 Under the XP system, if the software cannot be operated, please install

vcredist_x86.exe in the disc;

1.2 Under the W7 64 bit system, if the software cannot be operated, please install

vcredist_x64.exe

2. If the power light is not lit, and no operation can be made, then the power supply is

abnormal.

3. The output picture cannot be displayed, reason:

3.1 No input of signal;

3.2 The output wire is broken or exceeds the transferring distance.

Solve the problem:

1. Check the input signal source, confirm if the input signal channel is normal.

2. Check the OUT connecting output equipment, and IN connecting the input equipment;

3. Use high-quality cable to make sure stable and high quality image.

4. Cause for the differential color of the pictures:

4.1 The port is not well connected, which results in the poor touch.

4.2 Broken signal wire

4.3 Wrong color adjustment of the equipment

4.4 The color tune of the using software is incorrect

Solve the problem:

1. After the connecting the port, please tighten the screw and prevent the movement

caused by pulling;

2. Please replace with a good quality VGA line;

3. Adjust the color balance of the display equipment by referring to the manuals of the

display equipment

4. Re-adjust the color tune by controlling software.

5. Shaking and spotted images

Cause: 1. the cable is too long to make the despairing of the signal

2. Unstable input signal or the damaged wire.