RGBLink MVP 320 User Manual User Manual
Page 55

MVP 320 User Manual 55
corresponding physical units can be switched through ocov.
The resolution of the logical display is the set display resolution (set instruction), interval
between the adjacent logical displays can be set (the space can be 0, the image in the
space cannot be displayed) by the mode instruction.
Under each display mode, the attribution of the logical display is fixed, which is from left
to right, from top to bottom and start numbering from 0.
The logical display 0 left upper corner coordinate is(0,0), the resolution of the
hypothetical screen in the above example is 1280x1024,hgap,VGAp is 128, and the
coordinating of right down corner of logical display is
(1280X3+128X2-1,1024X3+128X2-1).
20. Check the IP address information instruction:
IP information of the return equipment
21. Correct the IP information instruction:
There are 20 parameters in this instruction, which is the IP address, MAC address,
covering code, gateway, terminal number (support 2 ports, but only one is in practical
use.)
Note:
A, turn the corresponding MAC address into decimal system, such as 6E->110。
B, This instruction only supports the correction of the network.
22. Put the content of the bit cushion zone into the related input channel
instruction:
front_color_B,back_color_R, back_color_G, back_color_B > SourceChl change the related input channel of the bit. Hstart is the horizontal starting place of the bit zone. Vstart is the vertical starting place of the bit zone. Mode is the bit accumulating mode, only the smallest two bits work, 0,2(the smallest bit is 0)is the un-accumulating bits. 1 is the un-accumulating bits, and the bit is the front