The ATY 261-351 DC room air

conditioning units have a REMKO

ATY...AT outdoor component as

well as an ATY...IT indoor unit.

When in cooling mode,

the outdoor component serves

to release the heat extracted

by the indoor unit from the

room being cooled. In heating

operation, the heat absorbed

by the outdoor component

can be discharged through

the indoor unit into the room

being heated. In both operating

modes, the performance of the

compressor precisely adjusts itself

to the demand, thereby regulating

the nominal temperature with

minimal temperature variations.

This "inverter-technology"

results in energy savings over

conventional split systems and

also reduces noise emissions

to a particularly low level. The

outdoor component can be

installed outdoors or indoors.

The latter requires the fulfilment

of certain conditions. The indoor

unit is designed to be mounted

high up on indoor walls. Operation

takes place using an infrared

remote control.

The outdoor component consists

of a refrigerant circuit with

compressor, fin condenser,

condenser fan, reverse flow valve

and throttle element. The outdoor

component is controlled via the

controller of the indoor unit.

The indoor unit consists of a fin

vaporiser, vaporiser fan, regulation

system and condensation pan.
Floor consoles, wall consoles,

refrigerant pipes and condensation

pumps are available as accessories.

Equipment description

The equipment is shipped in sturdy
transport packaging. Immediately
check the equipment on delivery
and make note of any damage
or missing parts on the delivery
note and inform the forwarding
agent and your contractual partner.
No warranty can be assumed
for later claims.

Transport and
Packaging

Refrigerant circuit diagram for the indoor unit

Vaporiser fan

Connection to suction pipe

Connection to injection line

Vaporiser

The connection between the indoor unit and the outdoor component is
made by way of the refrigerant lines.

Outdoor component

System configuration

Injection line

Indoor unit

Indoor area

Outdoor area

Stop valve

Condenser fan

Suction line

Condensation line

Condensation line

Electr. power supply line

Control line

Schematic of outdoor refrigerant circuit

M

M

Condenser fan

Reverse flow valve

Condenser

Filter dryer Flow regulator

Capillary tube

Connection valve

Injection line

Connection valve

Suction line

Compressor

5