Shutdown, Care and maintenance – REMKO ATY 261 DC User Manual
Page 15
Maintenance
■
We recommend concluding
a maintenance contract
with annual service from an
appropriate specialty company.
Shutdown
Temporary
Shutdown
1. Allow the indoor unit to run for 2
to 3 hours in air circulation
mode or in cooling mode at the
maximum temperature setting
in order to remove any residual
moisture from the unit.
2. Shut down the unit using the
remote control.
3. Switch off the voltage supply
to the unit.
4. Check the unit for visible
signs of damage and clean as
described in the chapter "Care
and maintenance".
Permanent
Shutdown
Ensure that equipment and
components are disposed
of in accordance with local
regulations, e.g. using certified
firms and recycling specialists or
at collection points.
REMKO GmbH & Co. KG or your
contractual partner will be pleased
to provide a list of certified firms
near you.
Care and maintenance
Regular care and maintenance
serves to ensure trouble-free
operation and long service life
of the unit.
Care and maintenance work
may only be carried out if the
unit is disconnected.
CAUTION
Care
■
Ensure the indoor unit and
outdoor component are
protected against dirt, mould
and other deposits.
■
Clean the equipment using
a damp cloth. Do not use any
caustic, abrasive or solvent-
based cleaning products. Do
not use a jet of water.
■
Before an extended shut down
period, clean the fins on the
outdoor unit and cover the
outdoor unit with plastic to
avoid infiltration of dirt into
the unit.
Cleaning the housing
of the indoor unit
1. Disconnect the supply voltage
to the equipment.
2. Clean the unit with a soft damp
cloth.
3. Switch the supply voltage back on.
Air filter for indoor unit
Clean the air filter at intervals of
no more than 2 weeks. Reduce this
interval in case of heavily soiled air.
Cleaning the filter on
the indoor unit
The indoor unit is equipped with
a filter with antibacterial coating.
The filter cleans the air of dust and
thereby reduces the distribution of
bacteria.
Prior to performing any work,
ensure the equipment is
disconnected from the voltage
supply and secured to prevent
accidental switch-on!
CAUTION
This ensures the operational
reliability of your system!
NOTE
Statutory regulations require
an annual leak test for the
refrigerant circuit in relation to
the refrigerant filling capacity.
Inspection and documentation
is to be carried out by
specialty technicians.
NOTE
15