Shutdown, Care and maintenance – REMKO ATY 261 DC User Manual

Page 15

background image

Maintenance

We recommend concluding
a maintenance contract
with annual service from an
appropriate specialty company.

Shutdown

Temporary
Shutdown

1. Allow the indoor unit to run for 2

to 3 hours in air circulation
mode or in cooling mode at the
maximum temperature setting
in order to remove any residual
moisture from the unit.

2. Shut down the unit using the

remote control.

3. Switch off the voltage supply

to the unit.

4. Check the unit for visible

signs of damage and clean as
described in the chapter "Care
and maintenance".

Permanent
Shutdown

Ensure that equipment and
components are disposed
of in accordance with local
regulations, e.g. using certified
firms and recycling specialists or
at collection points.

REMKO GmbH & Co. KG or your
contractual partner will be pleased
to provide a list of certified firms
near you.

Care and maintenance

Regular care and maintenance
serves to ensure trouble-free
operation and long service life
of the unit.

Care and maintenance work
may only be carried out if the
unit is disconnected.

CAUTION

Care

Ensure the indoor unit and
outdoor component are
protected against dirt, mould
and other deposits.

Clean the equipment using
a damp cloth. Do not use any
caustic, abrasive or solvent-
based cleaning products. Do
not use a jet of water.

Before an extended shut down
period, clean the fins on the
outdoor unit and cover the
outdoor unit with plastic to
avoid infiltration of dirt into
the unit.

Cleaning the housing
of the indoor unit

1. Disconnect the supply voltage

to the equipment.

2. Clean the unit with a soft damp

cloth.

3. Switch the supply voltage back on.

Air filter for indoor unit

Clean the air filter at intervals of

no more than 2 weeks. Reduce this

interval in case of heavily soiled air.

Cleaning the filter on
the indoor unit

The indoor unit is equipped with
a filter with antibacterial coating.
The filter cleans the air of dust and
thereby reduces the distribution of
bacteria.

Prior to performing any work,
ensure the equipment is
disconnected from the voltage
supply and secured to prevent
accidental switch-on!

CAUTION

This ensures the operational
reliability of your system!

NOTE

Statutory regulations require
an annual leak test for the
refrigerant circuit in relation to
the refrigerant filling capacity.
Inspection and documentation
is to be carried out by
specialty technicians.

NOTE

15