Technical data
Series
ATY 261 DC
ATY 351 DC
Operational mode
Inverter-wall room air conditioner combination for cooling and heating
Nominal cooling output
1)
kW
2,69 (1,00-2,93)
3,52 (1,2-3,87)
Nominal heating output
2)
kW
2,93 (1,00-3,20)
3,87 (1,20-4,10)
Energy efficiency class, cooling EER
1)
A
A
Energy efficiency class, heating COP
2)
A
B
Energy efficiency ratio EER
1)
3,68
3,56
Coefficient of performance COP
2)
3,64
3,49
Power consumption, annual, (500h) K / H
kWh
365
495
Operating range (room volume), approx.
m³
80
110
Refrigerant
R 410A
4)
R 410A
4)
Operating pressure, max. per cooling circuit
kPa
3800/1200
3800/1200
Power supply
V/Hz
230/1~/50
230/1~/50
Nom. electrical power consumption, cooling
1)
kW
0,75
0,99
Nom. electrical power consumption, heating
2)
kW
0,81
1,11
Elec. nominal power consumption cooling
1)
A
3,48
4,62
Elec. nominal power consumption heating
2)
A
4,00
5,21
Elec. starting current, max.
A
20
25
Refrigerant connection - injection line
Inches
(mm)
1/4 (6,35)
1/4 (6,35)
Coolant connection - suction line
Inches
(mm)
3/8 (9,52)
1/2 (12,7)
Data specific to
indoor unit
ATY 261 DC IT
ATY 351 DC IT
Operating range
°C/ %r.F
+16 to +32 / 80%
+16 to +32 / 80%
Adjustment range - Cooling
°C
+18 to +30
+18 to +30
Adjustment range - Heating
°C
+16 to +28
+16 to +28
Air flow volume per speed setting
m³/h
360/390/420
380/410/440
Protection class
IP
X0
X0
Sound pressure level per speed setting
3)
dB(A)
33/36/40
35/37/41
Dimensions - height
mm
567
567
Width
mm
567
567
Depth
mm
148
148
Weight
kg
12,0
12,0
Corresponding
outdoor component
ATY 261 DC AT
ATY 351 DC AT
Operating range - cooling
°C
+15 to +45
+15 to +45
Operating range - heating
°C
-7 to +24
-7 to +24
Air volume flow, max. K/H
m³/h
1340
1890
Protection class
IP
X4
X4
Sound pressure level, max.
3)
dB(A)
45
49
Refrigerant, basic quantity
4)
kg
410 A / 0.63
410 A / 0.83
Refrigerant, additional quantity > 5 m
g/m
20
20
Refrigerant line, max. length
m
15
15
Refrigerant line, max. height
m
5
5
Dimensions - height
mm
532
532
Width
mm
720
720
Depth
mm
245
245
Weight
kg
37,0
38,0
Serial number
937...
938...
EDP no.
1624261
1624351
1) Air inlet temperature TK 27°C / FK 19°C, outdoor temperature TK 35°C, FK 24°C, max. air flow volume, 5m line length, according to DIN EN14511
2) Air inlet temperature TK 20°C, outdoor temperature TK 7°C / FK 6°C, max. air flow volume, 5m line length, according to DIN EN14511
3) Distance 1 m free field
4) Contains greenhouse gas according to Kyoto protocol
31