In the air circulation mode, the air in the room is only circulated.
The room temperature cannot be changed in this mode. The cooling
or heating operation is not activated. The fan has four speeds. Neither
the ion generator nor turbo mode can be selected in this mode.

Air circulation MODE

AIR CIRCULATION

MODE

In the heating mode, you can heat the room in spring or fall. The desired
room temperature is set with buttons / in 1 °C increments. If the
room temperature is 1 °C below the selected nominal temperature, then
the indoor unit starts to warm up the air in the room. If the adjusted
room temperature is exceeded by approx. 0.5°C, then the controller
turns the heater function off. To protect the compressor, the controller
will not switch the heating on again until
it has waited for 3 minutes.

Heating MODE

> 6 Min.

> 3 Min.

> 6 Min.

30 sec.

30 sec.

Nominal temperature +5

°C

Nominal temperature +2

°C

Fan operation IT

Fan operation AT

Compressor operation AT

Actual temperature

Stop heating operation

Heating mode

Start heating mode

Functional diagram

Operation

Stop

Reverse flow valve

30 sec.

30 sec.

During the defrosting cycle, the indoor unit vaporiser fan and

the outdoor unit condenser fan are switched off.

After the cycle is concluded, the fans are switched to their previous

settings.

< 7 Min.

Defrost period

15 sec.

60 sec.

Fan operation IT

Fan operation AT

Compressor operation AT

Operation

Stop

Reverse flow valve

30 sec.

30 sec.

30 sec.

3 Min.

HEATING
OPERATION

MODE

MODE

REMKO ATY

10