Remko aty – REMKO ATY 261 DC User Manual
Page 16
Cleaning the condensation
pump (accessories)
An optional integrated or separate
condensation pump may be included
with the indoor unit, which pumps
out any accumulated condensation
into higher positioned drains.
Observe the care and maintenance
instructions given in the separate
operating instruction manual.
Type of task
Checks/Maintenance/Inspections
Commissioning
Monthly
Six-monthly
Yearly
General
•
•
Measure voltage and current
•
•
Check function of compressor
•
•
Check fan function
•
•
Contamination of evaporator fins
•
•
Check refrigerant fill quantity
•
•
Check condensation drain
•
•
Test insulation
•
•
Check moving parts
•
•
Sealing test for refrigerant circuit
•
•
1)
2 Open front cover
6 Cleaning with lukewarm water
1. Switch the indoor unit via the
remote control to air circulation
(the front cover of the air inlet
must be open!) (Figure 2).
2. Open the lower display cover
on the front side of the unit
by pressing both latches
and carefully fold the cover
downward and remove it from
the bracket (figure 3).
3. Push the clips on the filter up
and pull it out on the clips
(figure 4)
.
4. Clean the filter with a standard
vacuum cleaner. Turn the dirty
side upward (figure 5).
5. Carefully clean off any dirt in
lukewarm water and with mild
cleaner. Turn the dirty side
downwards (figure 6).
6. If water is used, let the filter dry
out air before replacing it in the
unit.
7. Carefully insert the filter. Make
sure it is seated correctly.
8. Close the display cover as
described above but in reverse
order.
9. Set the desired operating mode.
4 Pull out the filter
5 Cleaning using a vacuum cleaner
3 Remove the display cover
1) see note S.15
REMKO ATY
16