beautypg.com

Niveo Professional NGS16TP User Manual

Page 94

background image

90

NIVEO PROFESSIONAL Gigabit Management Switch

User's Manual

Mode: This is used to enable/disable Mirror function.
Monitering Port: This is used to set the capture port. The switch will copy the traffic
from Monitored Port to this port if Mirror function is enabled.
Monitored Port: This is the monitored port. The switch will copy the traffic from this
port to Monitoring Port.


5). Rate Control

Two traffic rates could be controlled by the switch. One is the ingress/egress traffic of
each port. Another is Broadcast/Multicast/Unicast Storm Control.

5-1) Rate Control Configuration
This function can setup the ingress and egress rate limit of ports.


Follow the steps to configure ...
a. Set “Unit” first. It could be selected from pre-defined units, or define by user. Click

[Apply] after the setting.

b. Select the Port Number.
c.

Enter the rate limit level for Ingress and Egress traffics. “0” means NO LIMIT. Click
[Apply] after the setting.


About “Packet Drop for Ingress Limit” function ...
When Ingress traffic rate exceeds Ingress Rate Limit, the switch can drop packets or
pause the traffic. If packet drop is enabled, flow control of ports will be disabled and
packets could be dropped. If packet drop is disabled, flow control of ports will be
enabled and pause frame will be sent when ingress traffic rate exceeds the limit.

5-2) Storm Control Configuration

This manual is related to the following products: