Niveo Professional NGS16TP User Manual
Page 63
59
NIVEO PROFESSIONAL Gigabit Management Switch
User's Manual
Good Unicast Frame 2001
Good Broadcast Frame 18
Good Multicast Frame 0
Discarded Frame
0
Errors
0
Total Transmit Byte Count 873047
show interface status command will show port status of all ports (one after another).
show interface status ethernet 1/x command will show port status of Port x. (“x” is
the port number).
For example,
# show interface status ethernet 1/5
Basic information:
Port type:
1000TX
Mac address:
00:11:22:64:99:6F
Configuration:
Name:
Port 5
Port admin:
Enable
Speed-duplex:
Auto_on
Capabilities:
10half,10full,100half,100full,1000full
Broadcast storm:
Disable
Flooded unicast storm:
Disable
Multicast storm:
Disable
Flow control:
Disable
Power saving:
Disable
LACP:
Disable
Max MAC count:
0
Maximum Packet Length: 9600
IPaddress Filter:
1
Current status:
Link status:
Up
Operation speed-duplex:
100Half
MDI/MDI-X:
Auto
show interface switchport command will show function configuration of all ports (one
after another).
show interface switchport ethernet 1/x command will show function configuration of
Port x. (“x” is the port number).
For example,
# show interface switchport ethernet 1/5
Information of Eth 1/5
Rate-limit level of input: 0
Ingress rate limit: Disable
Rate-limit level of output: 0
Egress rate limit: Disable
VLAN membership mode: access
VLAN stacking role: normal
Ingress rule: Disable
Acceptable frame type: All frames
Native VLAN: 1