beautypg.com

Niveo Professional NGS16TP User Manual

Page 81

background image

77

NIVEO PROFESSIONAL Gigabit Management Switch

User's Manual

Daylight Saving Time function will set the system time one-hour early than normal time
in a period of time. [Start Time] and [End Time] can be used to set the time period.


4). Log

[Configuration]


Users can configure System Log function and view log records here. If this function is
enabled, the switch will record events to a log file and put the log file to flash.

Up to 512 records are allowed for local logging. If more than 512 events happen, the
records will be overwritten from beginning. And if remote syslog server is applied, the
switch will also send event record to the syslog server.

About log function configuration ...
System Log Status : This can enable/disable system logging function.
Log Level (0~7) : Log levels 0~7 are defined as below. And events with lower log level
than this number will be recorded.

Level

Name

Description

0

Emergency

System is unusable

1

Alert

Action must be taken immediately

2

Critical

Critical conditions

3

Error

Error conditions

4

Warning

Warning conditions

5

Notice

Normal but significant condition

6

Informational

Informational messages

7

Debug

Debug-level messages

Remote Log : This can enable/disable remote syslog function.
Remote Log Server IP : This is the syslog server IP for remote logging. Up to five syslog