Counter section
Counter type
82C54
Configuration
82C54 device. 3 down-counters, 16 bits each
Counter 0 - Independent user counter
Source:
Internal 100 kHz or external (CTR 0 Clock In), software selectable
Gate:
External (Dig In 2 / CTR 0 Gate), software enabled
Output:
Available at user connector (CTR 0 Out)
Counter 1 - ADC Pacer Lower Divider
Source:
1 or 10 MHz oscillator, jumper selectable
Gate:
Tied to Counter 2 gate, programmable source: external (Dig In 0 /
Trigger) or internal
Output:
Chained to Counter 2 Clock.
Counter 2 - ADC Pacer Upper Divider
Source:
Counter 1 Output.
Gate:
Tied to Counter 1 gate, programmable source (external or internal).
Output:
ADC start convert, available at user connector (CTR 2 Out)
Clock input frequency
10 MHz max
High pulse width (clock input)
30 ns min
Low pulse width (clock input)
50 ns min
Gate width high
50 ns min
Gate width low
50 ns min
Input low voltage
0.8V max
Input high voltage
2.0V min
Output low voltage
0.4V max
Output high voltage
3.0V min
Environmental
Operating temperature range
0 to 50°C
Storage temperature range
-20 to 70°C
Humidity
0 to 95% non-condensing
30