Leprecon Litescape dimmer User Manual
Page 76
Litescape User’s Manual, Page 60
EDIT MONTH
EDIT DAY
EDIT YEAR
EDIT HOUR
EDIT MINUTE
Press UP or DOWN to modify the selected real time clock (RTC) parameter. When satisfied, press the
ENTER button to record the changes. To abort changes, press the PREV or NEXT buttons.
DEFAULT FADE
DEFAULT DELAY
Press UP or DOWN to modify the DEFAULT FADE TIME. The allowable values and resolutions are
INF
Infinite
0:00—0:59
1 second increments
1:00—9:59
5 second increments
10:00—60:00
15 second increments
When satisfied, you must press the ENTER button to record the changes. To abort changes, press the
PREV or NEXT buttons without pressing ENTER.
Clear Dimmers
Press UP or DOWN to toggle the select field to YES, then press ENTER to initiate the action. The “ARE
YOU SURE?” question will be displayed. Up to this point, the CLEAR can still be aborted by pressing the
PREV or NEXT buttons. To complete the initialization procedure, press the ENTER button.
The four system dimmers are initialized to DMX Base addresses of 1, 13, 25 and 37. All 12 channels on
each are set to the standard curve (
st).
Clear Scenes
Press UP or DOWN to toggle the select field to YES, then press ENTER to initiate the action. The “ARE
YOU SURE?” question will be displayed. Up to this point, the CLEAR can still be aborted by pressing the
PREV or NEXT buttons. To complete the initialization procedure, press the ENTER button.
The cue stack state is set to
off with a now scene of 1 and a nxt scene of 2. Scene ACTION is initialized
to
view.
Each scene is initialized to the default fade time and a delay time of
INF with all 48 channels at a level of
0. The scenes are linked in numerical sequence.
Clear All
Press UP or DOWN to toggle the select field to YES, then press ENTER to initiate the action. The “ARE
YOU SURE?” question will be displayed. Up to this point, the CLEAR can still be aborted by pressing the
PREV or NEXT buttons. To complete the initialization procedure, press the ENTER button.
The dimmer and cue stack variables are initialized to as described above. The Default Fade Time is
initialized to 0:05 seconds.
Memory Status
Press UP or DOWN to toggle the select field between
Open and Locked. When Locked, most
programmable features can be viewed but are unavailable for modification.