Installing a Litescape™ Architectural Series Houselite System
Litescape User’s Manual, Page 41
Set the
TERMINATION jumper to the disabled position, unless the panel is at the end of the cable run.
For button-only boards, verify that the
ANALOG JUMPER PLUG is present on the output connector P2.
This should have already been done at the factory.
Finally, the
HOUSE LIGHTS ENABLE DIP switch on all LWD2400s (not shown in above figure) must be
set the enabled position. Locate the 8-position DIP switch on the master LWD2400 and move switch #6
(third from the top) to the right. The LWD2400 must be restarted for this switch change to take effect.
Connecting the Wall Panel System Connector
The CAT5 interconnect cable should already be run and available at every location where a Houselite
panel will be installed.
The Wall Dimmer / Houselite system should be turned off whenever Houselite panels are connected to or
removed from the system. The maximum voltage at any wire on the BRDTalk © cable is only +12 volts
with respect to earth ground.
At the master LWD2400, or at any other HL Panel, identify the color coding of the four interconnect wires.
Attach in the same manner to the 4 pin terminal strip on the Wall Panel processor board
SYSTEM
CONNECTOR.
Connecting to the Wall Panel Aux Input Connector
This is an advanced feature and is not normally used. The 4-pin AUX INPUT CONNECTOR is available
for the user to attach the outputs from various devices such as proximity sensors, floor mats, limit
switches, etc.
Whether or not the PRIORITY KEYSWITCH is present on a Wall Panel, it should be a simple matter to
attach user input wires to the proper pins on the AUX INPUT CONNECTOR. If the KEYSWITCH OPTION
is not present, a suitable connector can be obtained at any electronics supply house or by contacting
LEPRECON and requesting part number 07-0096. If the PRIORITY KEYSWITCH is present, the
connector will already be present and user wires can be added to it. Care should be taken to splice into
the GROUND connection at pin 1 without disturbing the existing connections at pins 1 & 2.
Never attach
anything to pin 2, as it is already used for sensing the PRIORITY KEYSWITCH.
Only normally-open passive devices should be connected, such as the output from a relay or a switch.
When active, they should cause a short between GROUND (pin 1) and the desired CLOSURE pin (pin 3
or pin 4). There are two completely independent inputs available at each Wall Panel, for a total of 60 in a
full-up 30 panel system.
Installing the Wall Panel
Secure the Wall Panel to the electrical box. Holes are provided in the Wall Panel sheet metal for attaching
the factory-preassembled unit into standard electrical outlet boxes.
Clearing the Wall Panel Memory
If this is a first time Wall Panel installation, then the entire Wall Panel database should be cleared using
the LWD-2400 front panel interface. After energizing the system, locate the
system submenu, then
proceed to and activate the CLEAR ROOMS function.