Leprecon Litescape dimmer User Manual
Page 30
Litescape User’s Manual, Page 14
How to Troubleshoot Using the Status Menu on the LWD-2400
1
From
MAIN MENU press the right arrow key 3 times or until status blinks in the display.
2
Press
ENTER.
3
Note the
DMX STATUS, which will be not detected if there is no DMX input. Press ENTER to
examine the level for each DMX channel. Use the right and left arrow keys to move between
channels. To exit, press the left arrow repeatedly to return to the
DMX STATUS display.
4
Press the right arrow key from the
DMX STATUS display to view the PHASE STATUS. Press
ENTER to view the phase status for each phase. Press the left arrow repeatedly to return the PHASE
STATUS display.
5
Press the right arrow key from the
PHASE STATUS display to view the TEMP STATUS. See also
HOW TO CHECK THE TEMPERATURE OF LWD-2400 DIMMERS, above.
6
Press the right arrow key from the
TEMP STATUS display to view the HL PANEL STATUS display.
Note the number of wall panels in the entire system, and whether errors are detected
7
Press
ENTER to view statuses for individual wall panels. Use the up or down arrow key to move
between wall panels. Each wall panel in the system is identified by its room number (
RM) and panel
number within the room (
PNL).
8
When positioned to view the room number and panel number of interest, press the right arrow key
three times to view the number of
ERRORS for that specific wall panel. Press ENTER to set this to
zero. If the number increments while you watch it, there is a problem with the wiring, multiple panels
are set to the same number, or one or more devices need to be terminated.
9
Press the right arrow key once more to view the status of the panel keys. The
KEY corresponds to
the present button number, and will be displayed as
off if the preset doesn’t exist. Use the up and
down arrow keys to view the
on or off status for each preset. Please note that the ON status will only
be shown as long as the button is held down.
KEY 13 corresponds to the off button.
10 From the KEY status display, press the right arrow key one time to view the status of each FADER on
the panel. Use the up and down arrow to move between faders. The status is 0 is the fader is not
present, and the status is a number from 2 to 254 for valid faders. This allows one to view how many
faders exist on a remote wall panel, and their current levels.
11 To exit, press the left arrow key repeatedly (approximately 10 times) to return to the MAIN MENU.